2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508
2通道隔離屏障,24 V直流電源(電源軌),干接點或NAMUR輸入,繼電器觸點輸出,線路故障檢測(LFD),可逆的操作模式,通過SIL2 ACC。 IEC61508,輸入:NAMUR傳感器,額定電壓:20...直流30 V,輸出:繼電器,SIL/ IEC 61508標(biāo)準(zhǔn)
數(shù)字輸入信號類型
供應(yīng)
連接電源導(dǎo)軌或端子14 +,15 -
額定電壓20 ... 30 V直流
紋波≤10%
額定電流≤50毫安
1瓦的功率損耗
功耗<1.3 W
輸入
接線端子1 +,2 +,3 - 4 +,5 +,6 -
額定值A(chǔ)CC。 EN 60947-5-6(NAMUR標(biāo)準(zhǔn))
開路電壓/短路電流約。 8 V直流/約。 8 mA的
開關(guān)點/開關(guān)遲滯1.2 ... 2.1毫安/大約。 0.2 mA的
線路故障檢測破損我≤0.1毫安,短路我> 6 mA的
脈沖/間歇比例分鐘。 20毫秒/分鐘。 20毫秒
產(chǎn)量
連接輸出端子7,8,9,輸出端子10,11,12
輸出I,II信號,繼電器
小開關(guān)電流2毫安/ 24伏直流
通電/斷電延時約。 /約20毫秒。 20毫秒
機械壽命107開關(guān)周期
傳輸特性
開關(guān)頻率≤10赫茲
指令符合
電磁兼容性
指令2004/108/EC EN 61326-1:2006
低電壓
指令2006/95/EC EN 61010-1:2010
一致性
電磁兼容性NE 21
防護等級符合IEC 60529
環(huán)境條件
環(huán)境溫度-20 ...- 60°C(-4 ... 140℉)
機械規(guī)格
防護等級IP20
質(zhì)量約。 150公克
尺寸20×119×115毫米(0.8×4.7×4.5),住房B2型
安裝在35毫米DIN安裝軌ACC。 DIN EN 60715標(biāo)準(zhǔn)
數(shù)據(jù)連接前區(qū)的應(yīng)用
EC型式檢驗證書肺結(jié)核00 A??TEX認證2080年,其他證書見
集團,類別,類型II(1)政[EX IA] IIC,二(0)D [防爆IA] IIIC部保護
聲明符合PEPPERL + Fuchs公司
集團,類別,保護II型(3)政[EX IC] IIC; [前NL] IIC
聲明符合TÜV99 ATEX 1493 X,觀察符合性聲明
集團,類別,類型的保護,溫度II類3G前nA的數(shù)控IIC T4。
指令符合
指令94/9/EC EN 60079-0:2009,EN 60079-11:2007,EN 60079-15:2005,EN 61241-11:2006
國際認證
FM認證
控制繪圖116-0035
CSA認證
控制繪圖116-0047
IECEx認證批準(zhǔn)IECEx認證肺結(jié)核11.0034
批準(zhǔn)前IA] IIC的,[防爆IA] IIIC部,[防爆IA]
德國P+F隔離柵,KFD2-SR2-Ex2W
Signal type Digital Input
Supply
Connection Power Rail or terminals 14+, 15-
Rated voltage 20 ... 30 V DC
Ripple ≤ 10 %
Rated current ≤ 50 mA
Power loss 1 W
Power consumption < 1.3 W
Input
Connection terminals 1+, 2+, 3-; 4+, 5+, 6-
Rated values acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detection breakage I ≤ 0.1 mA , short-circuit I > 6 mA
Pulse/Pause ratio min. 20 ms / min. 20 ms
Output
Connection output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output I, II signal, relay
Minimum switch current 2 mA / 24 V DC
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Mechanical life 107 switching cycles
Transfer characteristics
Switching frequency ≤ 10 Hz
Directive conformity
Electromagnetic compatibility
Directive 2004/108/EC EN 61326-1:2006
Low voltage
Directive 2006/95/EC EN 61010-1:2010
Conformity
Electromagnetic compatibility NE 21
Protection degree IEC 60529
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Protection degree IP20
Mass approx. 150 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 in) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to DIN EN 60715
Data for application in connection with Ex-areas
EC-Type Examination Certificate PTB 00 ATEX 2080 , for additional certificates see
Group, category, type of protection II (1) G [Ex ia] IIC, II (1) D [Ex ia] IIIC
Statement of conformity Pepperl+Fuchs
Group, category, type of protection II (3)G [Ex ic] IIC; [Ex nL] IIC
Statement of conformity TÜV 99 ATEX 1493 X , observe statement of conformity
Group, category, type of protection, temperature class II 3G Ex nA nC IIC T4
Directive conformity
Directive 94/9/EC EN 60079-0:2009, EN 60079-11:2007 , EN 60079-15:2005 , EN 61241-11:2006
International approvals
FM approval
Control drawing 116-0035
CSA approval
Control drawing 116-0047
IECEx approval IECEx PTB 11.0034
Approved for [Ex ia] IIC , [Ex ia] IIIC , [Ex ia]